Specifications |
TruSense S100 |
TruSense S200 Series
|
|
Performance |
Min range |
1.5 ft (0.46 m) |
1.5 ft (46 cm) |
Max range (To reflective target / To non-reflective target) |
7,546 ft / 5,249 ft
(2,300 m / 1,600 m) |
9,514 ft / 5,249 ft (2,900 m / 1,600 m) low-accuracy mode
4,921 ft / 2,953 ft (1500 m / 900 m) medium-accuracy mode
2,461 ft / 2,461 ft (750 m / 750 m) high- accuracy mode
|
Accuracy |
3.3 ft (1 m) |
0.1 ft (4 cm) short-range mode
0.3 ft (8 cm) medium-range mode
0.5 ft (15 cm) long-range mode
|
Data output rate |
<1 Hz to 6 Hz
|
< 1 Hz to 14 Hz
|
Target modes |
Closest, Farthest, Closest-Farthest, Strongest, First |
First, Strongest, Last, First-second-third, Last-second-to-last, First-strongest-last, First-second-third-strongest-last |
|
Optical and Electrical |
Wavelength |
905 nm (near IR) |
905 nm (near IR) |
Divergence |
3 mrad (equal to 1 ft beam diameter @ 328 ft (30 cm @ 100 m) |
3 mrad (equal to 1 ft beam diameter @ 328 ft (30 cm @ 100 m) |
I/O |
RS232
|
S-200 = TRIG, SDI12, RS232 w/o alignment laser
S-210 = TRIG, SDI12, RS232 w/ alignment laser
S-230 = 4-20, 4-20 HART w/ alignment laser
|
Baud rate min/max |
9,600 / 230,400 |
9,600 / 230,400 |
Input power |
9 VDC |
12 VDC |
Current draw |
Measuring = 150 mA, Idle = 50 mA, Sleep = 30 mA |
Measuring = 150 mA,
Standby = 40 mA |
|
Physical |
Dimensions ( L x W x H) |
4.11 x 3.22 x 1.64 in
(104.4 x 81.7 x 41.6 mm) |
4.11 x 3.22 x 1.64 in
(104.4 x 81.7 x 41.6 mm) |
Weight |
Standard = 4.8 oz (138.6 g),
OEM = 2.7 oz (76 g) |
Standard = 4.8 oz (138.6 g),
OEM = 2.7 oz (76 g)
|
Housing and frame material |
Glass-filled polycarbonate |
Glass-filled polycarbonate |
|
Environmental |
Eye safety |
Class 1, 7 mm (FDA, CFR21)
Class 1m (IEC 60825-1:2001) |
Class 1, 7 mm (FDA, CFR21)
Class 1m (IEC 60825-1:2001) |
Moisture |
IP54 |
IP54 |
Operating temperature |
- 20° to 140° F
(- 28° to 60° C) |
- 20° to 140° F
(- 28° to 60° C) |
Shock/Vibration |
MIL-STD-810 |
MIL-STD-810 |