TruSense T-Series Specifications
|
|
|
TruSense T-Series Laser Sensors Specifications
Performance |
Min range |
46 cm (1.5 ft) |
Max range (To reflective target / To non-reflective target) |
50 m (165 ft)
|
Accuracy |
distance = +/- 10 cm (3.9 in) dual sensor speed = 2% w/ 75 cm spacing
|
Data output rate |
<1 Hz to 25 kHz: Depending upon RS232 or RS485 |
Target modes |
Profile, speed (dual sensors), Time between vehicles (TBV), height, length, distance
|
Optical and Electrical |
Wavelength |
905 nm (near IR) |
Divergence |
3 mrad (equal to 1 ft beam diameter @ 328 ft (30 cm @ 100 m) |
I/O |
RS232, RS485, TRIG
|
Baud rate min/max |
1,200 / 230,400
|
Input power |
12 VDC |
Physical |
Current draw |
Measuring = 150 mA |
Dimensions ( L x W x H) |
172.7 x 73.7 x 114.3 mm (6.8 x 2.9 x 4.5 in) |
Weight |
Standard = 517.10 g (18.2 oz) |
Housing and frame material |
Glass-filled polycarbonate
|
Environmental |
Eye safety |
Class 1, 7mm (FDA, CFR21) Class 1m (IEC 60825-1:2001) |
Moisture |
IP54 |
Operating temperature |
- 28 to 60° C (- 20° to 140° F) |
Shock/Vibration |
MIL-STD-810 |
NOTE: All specifications are subject to change without notice.
Installation requires integrator to install within separate housing or underneath canopy (not included) to protect sensor and sensor connections from exposure to environmental elements such as rain, snow, and ice.
|
|
|
|
|
|
|
|